NAVIGATION (FIRE APPLIANCES) REGULATIONS 1968 - REG 59
Breathing apparatus
- (1)
- Subject to subregulation (2), the breathing apparatus referred to in
regulation 58 may consist of:
- (a)
- a smoke helmet or smoke mask together
with:
- (i)
- a length of non-collapsible air hose sufficient in length to
enable the inlet end to be on deck clear of hatches and doorways and in clean
air while the wearer of the helmet or mask is in any part of the cargo, crew,
machinery or passenger space, as the case requires, but not exceeding 36
metres in length; and
- (ii)
- a pump suitable for pumping air through the hose;
or
- (b)
- self-contained breathing apparatus capable of delivering an
uninterrupted supply of not less than 1,500 litres of free air measured at a
temperature of 15° Celsius and at atmospheric pressure.
- (2)
- Where the distance between a place on deck clear of hatches and doorways
and in clean air and any part of the cargo, crew, machinery or passenger
space, as the case requires, exceeds 36 metres, not less than one-half of
the number of firemen's outfits required to be furnished in accordance with
regulations 16 and 30 shall include a self-contained breathing apparatus of
the type referred to in paragraph (1) (b).
- (3)
- A breathing apparatus required by these Regulations to be furnished in a
ship shall be of an approved type.
- (4)
- A breathing apparatus furnished in a ship in accordance with these
Regulations shall have attached to the belt or harness, by means of a snap
hook, a fire proof life-and-signalling line at least 3 metres longer than the
distance between a position on deck clear of hatches and doorways and in clean
air and any part of the cargo, crew, machinery or passenger space, as the case
requires.
- (5)
- A line provided in a ship in accordance with subregulation (4) shall be
made of hemp-covered wire rope not less than 10 millimetres in diameter
that incorporates a wire that:
- (a)
- is made of copper or galvanized steel;
and
- (b)
- has a breaking strength of not less than 5 kilonewtons.
- (6)
- Efficient couplings shall be provided if 2 or more lengths of hose are
joined.
- (7)
- The inlet end of the pump shall be so protected that the supply of air
cannot be obstructed.