Commonwealth Consolidated Regulations

[Index] [Table] [Search] [Search this Regulation] [Notes] [Noteup] [Previous] [Next] [Download] [Help]

NAVIGATION (CONSTRUCTION) REGULATIONS 1968 - REG 99

Bilge strum boxes

(1)
Where the suction end of a bilge suction pipe is in a hold space or a tunnel well, the end shall be enclosed in a strum box.

(2)
A strum box referred to in the last preceding subregulation:

(a)
shall be provided with perforations:

(i)
each of which shall be approximately three-eighths of an inch in diameter; and
(ii)
the combined area of which shall be not less than twice the area of the end of the bilge suction pipe; and
(b)
shall be so constructed that it can be cleared without breaking any joint of the bilge suction pipe.