Western Australian Consolidated Regulations (1) A lighter must
comply with subregulation (2) after being tested in accordance with the
procedures described in Schedule 1 Divisions 3, 4 and 5.
(2) For
subregulation (1), where —
(a) a
non‑adjustable lighter produces a flame for 10 seconds; or
(b) an
adjustable lighter —
(i)
produces a flame for 5 seconds at the maximum flame
height adjustment; or
(ii)
produces a flame for 10 seconds at the minimum flame
height adjustment,
the flame produced
must extinguish after cessation of the action sustaining the flame within 2
seconds if the lighter has no flameguard or 4 seconds if it has a flameguard.
[Regulation 8 inserted in Gazette 28 May
2010 p. 2348‑9.]