Western Australian Consolidated Regulations[r. 75]
[Heading inserted in Gazette 30 Dec 2008
p. 5637.]
[Heading inserted in Gazette 30 Dec 2008
p. 5637.]
Australian/New Zealand
Standard AS/NZS 2195:1999 “Folding cots — Safety
requirements” published by Standards Australia on
15 November 1999.
[Clause 1 inserted in Gazette
30 Dec 2008 p. 5637.]
Division 2 — Variations to AS/NZS 2195:1999
[Heading inserted in Gazette 30 Dec 2008
p. 5637.]
Delete the second
paragraph of the foreword.
[Clause 2 inserted in Gazette
30 Dec 2008 p. 5637.]
In clause 1 delete all
of the text after “for folding cots”.
[Clause 3 inserted in Gazette
30 Dec 2008 p. 5637.]
Delete clauses 2,
3, 5 and 6.
[Clause 4 inserted in Gazette
30 Dec 2008 p. 5637.]
Delete clause 7
and insert the following clause instead —
“
7 CONSTRUCTION AND ASSEMBLY
The cot mattress and
components within the cot shall not be of inflatable construction.
”.
[Clause 5 inserted in Gazette
30 Dec 2008 p. 5637.]
(1) In
clause 8.1(b) delete the Note.
(2) In
clause 8.1(d) —
(a)
delete “on warning labels specified in Clauses 12.1(i), 12.2 and
13.2(b) (measured horizontally)”; and
(b)
delete Note 2.
(3) In
clause 8.3(a) delete the Note.
(4) Delete
clause 8.3(b).
(5) In
clause 8.3(c) delete the Note.
(6) In
clause 8.4.1 delete “distinct locking position.” and insert
instead —
“ clearly distinct locked position. ”.
(7) Delete
clause 8.4.2 including Figure 1.
(8) In
clause 8.4.3 —
(a) in
paragraph (e) delete “before and after being tested in accordance
with Appendix G”; and
(b)
delete the Note.
(9) Delete
clauses 8.5, 8.6 and 8.7.
[Clause 6 inserted in Gazette
30 Dec 2008 p. 5637‑8.]
Delete clause 9.
[Clause 7 inserted in Gazette
30 Dec 2008 p. 5638.]
(1) Delete
clauses 10.1 and 10.2 including Figure 2 and insert the following clauses
instead —
“
10.1 General The
applicable tests specified in clauses 10.2, 10.5, 10.13 and 10.14 shall
be performed on the same folding cot assembled in accordance with the
manufacturer’s instructions and without any accessories fitted.
10.2 Entrapment hazard
test The folding cot shall be tested in accordance with Appendix A using the
95 mm probe. All gaps accessible within the folding cot shall not allow
the 95 mm probe to pass through.
”.
(2) Delete
clauses 10.3, 10.4, 10.6, 10.7, 10.8, 10.9, 10.10, 10.11 and 10.12.
(3) In
clause 10.13(c) delete “500 mm” and insert
instead —
“ 400 mm ”.
(4) Delete
clauses 10.15 and 10.16.
[Clause 8 inserted in Gazette
30 Dec 2008 p. 5638.]
Delete clauses 11
and 12.
[Clause 9 inserted in Gazette
30 Dec 2008 p. 5638.]
(1) Delete
clause 13.1.
(2) Delete
clause 13.2 and insert instead —
“
13.2 Safety marking
The cot shall be permanently, prominently and legibly marked on the inside of
the cot with at least:
(a)
instructions for assembly and locking procedures;
(b) a
warning to check before each use that the cot is correctly assembled and
locking devices are fully engaged;
(c)
either a warning to use a mattress of specified dimensions or a warning to use
the mattress supplied by the manufacturer; and
(d) a
warning not to add an extra mattress as this may cause suffocation.
”.
(3) Delete
clauses 13.3 and 13.4.
[Clause 10 inserted in Gazette
30 Dec 2008 p. 5639.]
(1) In Appendix A
clause A1 delete the words “finger, limb and”.
(2) In Appendix A
clause A2 —
(a)
delete “A series of probes are” and insert instead —
“ A probe is ”; and
(b)
delete “to the probes” and insert instead —
“ to the probe ”; and
(c)
delete Notes 1 and 2.
(3) Delete Appendix A
clause A3 and insert instead —
“
A3 APPARATUS The
following apparatus is required:
(a) A
spherical probe made of a suitably rigid material having a diameter of 95
± 0.5 mm. The probe may be mounted on a rod of diameter not greater
than 15 mm for the purpose of applying the specified force.
(b) A
means of applying a force of 50 ± 5N.
”.
(4) In Appendix A
delete clause A4 (e), (f), (g), (h), (i), (j), (k), (l), (m), (n) and (o).
(5) In Appendix A
delete clause A5 (b), (c) and (d).
[Clause 11 inserted in Gazette
30 Dec 2008 p. 5639.]
12 . Appendices B, D, E, F, G, H, I, J, M and N
Delete Appendices B,
D, E, F, G, H, I, J, M and N.
[Clause 12 inserted in Gazette
30 Dec 2008 p. 5639.]