Western Australian Consolidated Regulations

[Index] [Table] [Search] [Search this Regulation] [Notes] [Noteup] [Previous] [Next] [Download] [Help]

MINES SAFETY AND INSPECTION REGULATIONS 1995 - REG 11.3

11.3 .         Notice of intention to install winding system

        (1)         Before any winding system for the transportation of persons, materials or rock is installed, erected or re‑erected in a mine, each responsible person at the mine must ensure that — 

            (a)         the State mining engineer is notified in writing of the intention to construct, erect or re‑erect the winding system;

            (b)         plans showing the location of the shaft together with the general layout of the system are submitted to the State mining engineer; and

            (c)         details of the design of the various components of the winding installation are submitted to the State mining engineer including details of — 

                  (i)         winding machinery;

                  (ii)         shaft conveyances, which show that they comply with AS 3785.4;

                  (iii)         winding ropes;

                  (iv)         winding rope terminations or cappings, which show that they comply with AS 3637.3;

                  (v)         headframes, which show that they comply with AS 3785.5;

                  (vi)         headframe overwind provisions;

                  (vii)         shaft conveyance guiding systems, which show that they comply with AS 3785.6;

                  (viii)         associated surface bins; and

                  (ix)         sheaves, which show that they comply with AS 3785.7.

        (2)         The State mining engineer may require the provision of design information additional to that provided under subregulation (1).

        (3)         Each responsible person at a mine must ensure that a requirement made under subregulation (2) is complied with within one month after the day on which it is made.

        Penalty: See regulation 17.1.

        (4)         This regulation does not apply to the installation, erection or re‑erection of hoists to be used for — 

            (a)         winze sinking;

            (b)         rising;

            (c)         stope servicing; or

            (d)         any other similar purpose.